Monday, February 6, 2012

GE Fanuc PLC Control For 3 Movement




PLC Type GE Fanuc Series 90 Micro, Name of the Input / Output:

PLC Input:
%I0001 ; Push Button Start
%I0002 ; Sensor1 Reverse
%I0003 ; Sensor1 Forward
%I0004 ; Sensor2 Reverse
%I0005 ; Sensor2 Forward
%I0006 ; Emergency Stop (Push Button)

PLC Output:
%Q0001 ; Cylinder1 Forward
%Q0002 ; Cylinder1 Reverse
%Q0003 ; Cylinder2 Forward
%Q0004 ; Cylinder2 Reverse


Download PDF File:
GE Fanuc PLC For 3 Movement(.pdf)

Please Download Programming for Logicmaster 90 :
GE Fanuc PLC Control for 3 movement

Reading Ladder PLC Programming for 3 movement with Standard Sequence Programming :

1. INPUT CONDITION
a.If %I0006 = ON Then %M0001 = ON
b.If %M0001 = ON Then R UPCTR %R0001 or %R0001 = 0 (Only STEP0 = ON)
c.If %I0002 = ON AND %I0004 = ON Then %M0002 = ON ( ALL ORIGIN = ON)
d.If %I0001 = ON Then %M0003 = ON (Start = ON)

2. TRIGGER AND SENSOR CONDITION
a.If %M0010 = ON AND %M0002 = ON AND %M0003 = ON Then %M0004 = ON AND %M0011 = ON (STEP1 = ON)
b.If %M0011 = ON AND %I0003 = OFF Then %M0004 = OFF AND Waiting STEP1
c.If %M0011 = ON AND %I0003 = ON Then %M0004 = ON AND %M0012 = ON (STEP2 = ON)
d.If %M0012 = ON AND %I0005 = OFF Then %M0004 = OFF AND Waiting STEP2
e.If %M0012 = ON AND %I0005 = ON Then %M0004 = ON AND %M0013 = ON (STEP3 = ON)
f.If %M0013 = ON AND %I0002 = ON AND %I0004 = ON Then %M0010 = ON (STEP0 = ON) Else Waiting STEP3

3. OUTPUT CONDITION
a.If %M0011 = ON Then %Q0001= ON
b.If %M0013 = ON Then %Q0002 = ON
c.If %M0012 = ON Then %Q0003 = ON
d.If %M0013 = ON Then %Q0004 = ON

4. CONTROLLER
a.If %M0011 = OFF AND %M0012 = OFF AND %M0013 = OFF Then %M0005 = ON (Only STEP0 = ON)
b.If %M0005 = ON AND %R0001 Not Equal 0 (Null) Then MOVE %R0001 = 0 (Only STEP0 = ON)
c.If %M0004 = ON (Trigger) Then UPCTR %R0001
d.If %M0001 = ON (Emergency Stop) Then R UPCTR %R0001 or %R0001 = 0 (Only STEP0 = ON)
e.If %R0001 = 0 Then %M0010 = ON (STEP0 = ON)
f.If %R0001 = 1 Then %M0011 = ON (STEP1 = ON)
g.If %R0001 = 2 Then %M0012 = ON (STEP2 = ON)
h.If %R0001 = 3 Then %M0013 = ON (STEP3 = ON)

Back to : PLC Control for 3 movement