PLC Type CP1L, Name Input / Output PLC :

INPUT PLC :
I: 0.00 ; Push Button Start
I: 0.01 ; Sensor1 Reverse
I: 0.02 ; Sensor1 Forward
I: 0.03 ; Sensor2 Reverse
I: 0.04 ; Sensor2 Forward
I: 0.05 ; Emergency Stop (Push Button)

OUTPUT PLC :
Q: 100.00 ; Cylinder1 Forward
Q: 100.01 ; Cylinder1 Reverse
Q: 100.02 ; Cylinder2 Forward
Q: 100.03 ; Cylinder2 Reverse


Download PDF File:
Omron PLC For 3 Movement(.pdf)

Please Download Programming for CX-Programmer v9.1 :
Omron PLC Control for 3 movement

Reading Ladder PLC Programming for 3 movement with Standard Sequence Programming :

1. INPUT CONDITION
a.If I: 0.05 = ON Then 10.00 = ON
b.If 10.00 = ON Then Reset Input C0 or C0 = 0 (Only STEP0 = ON)
c.If I: 0.01 = ON AND I: 0.03 = ON Then 10.01 = ON ( ALL ORIGIN = ON)
d.If I: 0.00 = ON Then 10.02 = ON (Start = ON)

2. TRIGGER AND SENSOR CONDITION
a.If 11.00 = ON AND 10.01 = ON AND 10.02 = ON Then 10.03 = ON AND 11.01 = ON (STEP1 = ON)
b.If 11.01 = ON AND I: 0.02 = OFF Then 10.03 = OFF AND Waiting STEP1
c.If 11.01 = ON AND I: 0.02 = ON Then 10.03 = ON AND 11.02 = ON (STEP2 = ON)
d.If 11.02 = ON AND I: 0.04 = OFF Then 10.03 = OFF AND Waiting STEP2
e.If 11.02 = ON AND I: 0.04 = ON Then 10.03 = ON AND 11.03 = ON (STEP3 = ON)
f.If 11.03 = ON AND I: 0.01 = ON AND I: 0.03 = ON Then 11.00 = ON (STEP0 = ON) Else Waiting STEP3

3. OUTPUT CONDITION
a.If 11.01 = ON Then Q: 100.00 = ON
b.If 11.03 = ON Then Q: 100.01 = ON
c.If 11.02 = ON Then Q: 100.02 = ON
d.If 11.03 = ON Then Q: 100.03 = ON

4. CONTROLLER
a.If 11.01 = OFF AND 11.02 = OFF AND 11.03 = OFF Then 10.04 = ON (Only STEP0 = ON)
b.If 10.03 = ON (Trigger) Then Count Input CNT0000 = ON
c.If 10.00 = ON (Emergency Stop) Then Reset Input CNT0000 or CNT0000 = 1000 (Only STEP0 = ON)
d.If 10.04 = ON AND C0 (CNT0000) Not Equal 1000 (#1000) Then Reset Input CNT0000 or CNT0000 = 1000 (Only STEP0 = ON)
e.If C0 (CNT0000) = 1000 (#1000) Then 11.00 = ON (STEP0 = ON)
f.If C0 (CNT0000) = 999 (#999) Then 11.01 = ON (STEP1 = ON)
g.If C0 (CNT0000) = 998 (#998) Then 11.02 = ON (STEP2 = ON)
h.If C0 (CNT0000) = 997 (#997) Then 11.03 = ON (STEP3 = ON)

Omron PLC programming for Control 3 movement
with Standard Sequence Programming



Back to : PLC Control for 3 movement


Labels:

Newer Post Older Post Home

You may also like these ebook:

Get Free PLC eBook directly sent to your email,
and email subscription to program-plc.blogspot.com




We hate SPAM. Your information is never sold or shared with anyone.

Your Email Will Be 100% Secured !

Your email is stored safely on Google FeedBurner