Installation Instructions for Allen Bradley ControlNet





A PLC (programmable logic controller) is an electronic device that be similar to a computer and is utilized to check particular incoming and outgoing actions. The devices can be utilized for any processes number, including monitoring fluid levels or temperatures, livestock water and feedings automating and even to control synchronized or timed lighting setups. An Allen Bradley PLC comes with its own operating system. Most of the required supplies are comprised with the Allen Bradley PLC. Setting up a PLC is a technical process;
1. Take out any power input source from the hardware. Switch the power to the position OFF when working with hardware. Change the switches of backplane to the suitable settings. This will differ between users. Turn Switch 1 to the position ON. This controls whether the outputs stay in their state of current in a failure event. Turn Switch 1 to the position OFF also will switch the outputs off in failure case. Switches 2 and 3 always should stay in the position OFF. Put switches 4 and 5 manage the slots number you will be using. Turning on 4 and 5 concurrently is not permissible. Turn off switches 6 and 7 to shift memory at power up.


2. Enter the chassis to recognize the proper module of power supply. Use the plastic bands that sent with the system. Slip the keying bands between 40 - 42 and again between 54 - 56. Place the module power between the key bands, and depress the module tightly into the slot of chassis. Swing the latch placed on the chassis slot end closed to protect the module power in place.
3. Get ground the chassis to the chassis mounting bolt connected to the area wall. Take out the nut and bolt with a wrench. Use the wrench to take away any paint where the bolt head would rest. Fit a washer star on the bolt and put in it back into the chassis. Slip the lug ground and conductor equipment from the module power on the bolt, chased by a second washer star, and protect the assembly with the nut.
4. Take out the cover door of battery from the chassis side using a screwdriver Phillips to take off it. Join the supplied battery to the connector cable of battery and put in the battery into the slot. Attach back the cover door of battery and tighten the screw into position.
5. Place the switches of Station Address on the processor back. Press on the station address switch down if using station of 57.6 Kbaud or slip it up if using a station of 230 Kbaud looking at the processor from the side.
6. Place the two knobs of ControlNet. Locate the left knob to 00 and put the right knob to 1. These are the settings default for the address of processors' NET.
7. Mount the chassis into the container assembly by forcing out the side wings on the locking bar. Lift up the bar with the wings softly pushed out. Discharge the wings and slip the chassis into an open slot along the card guides pair inside the container. Press on the locking wings back out and fasten the bar back into position
8. Depress the button Power on the container front side to power up the system. When the LED turns on red, it should keep on to indicate proper function. Join the system to the computer with the provided cable of Ethernet. Connect one of the cable end into the slot of Ethernet on the system of PLC and the reverse end straight into the hub of computer or Ethernet.