Panasonic Air Flow Monitor EWA2 will do the job to Visualize Compressed Air and Nitrogen Gas (N2) Consumption in order to Identify and Eliminate Waste. The compressor typically requires more electricity to run than other equipment. Reducing the power consumption of the air compressor is the main goal of any energy savings plan. Moreover, in general, the air leakage for up to 20 to 25% of the air to use in general accounts. Depicting water consumption to identify and eliminate waste.
You can install the types of ultrasound and control the panasonic Air Flow Monitor of air on each compressor to control air leakage. It will provide and improve the overall operational efficiency of the compressor.
Nitrogen gas can be measured to the compressed air, it has added the ability to measure the high cost of nitrogen gas. Air leakage from the pipeline can be detected and the ability to supply air compressor can be optimized to reduce energy waste. This product can measure nitrogen gas with a small or medium pipe sizes only.
Panasonic Air Flow Monitor EWA2 has selected function to convert the flow. For the normal flow, the volumetric flow rate per unit time at 0 ℃, 1 atm (atmospheric pressure). While for record flow, the volumetric flow rate per unit time at a temperature range (℃) (1), ATM (atmospheric pressure)
1. Zero energy losses
Any obstacles in the measurement of the pipe system for ultrasonic detection, causing a loss of pressure zero.
2. Zero energy losses
R.S. (Meter reading) Accuracy applies the accuracy of all readings in the range of flow rates. Therefore, the flow rate in the range until the low flow rate can be read with high accuracy.
3. It can be used in the loop pipes
It can measure the live broadcast and vice versa. Can be measured is transferred between buildings air consumption.
4. It can be used in plumbing circles
Pulse output and analog output current is available. It can be used for the connection.
1. Connect the output pulse of air flow control Aako- POWER meters.
2. Display the graph of electricity, heat, compressed air and the use of nitrogen gas. It includes the other data that have been collected by the light of the data recorder (DLL) using computer programs KW observer. This helps to use air / nitrogen compressed gas from several viewpoints electrical analysis.
You can install the types of ultrasound and control the panasonic Air Flow Monitor of air on each compressor to control air leakage. It will provide and improve the overall operational efficiency of the compressor.
Panasonic Air Flow Monitor EWA2 is easy to use, with high durability
Panasonic Air Flow Monitor EWA2 is easy to use because the sensors adopted ultrasonic detection principle, such as there is no need filter can also be air contains oil spray can be measured. Blot the sensor resistance, and there is no need of maintenanceNitrogen gas can be measured to the compressed air, it has added the ability to measure the high cost of nitrogen gas. Air leakage from the pipeline can be detected and the ability to supply air compressor can be optimized to reduce energy waste. This product can measure nitrogen gas with a small or medium pipe sizes only.
Panasonic Air Flow Monitor EWA2 has selected function to convert the flow. For the normal flow, the volumetric flow rate per unit time at 0 ℃, 1 atm (atmospheric pressure). While for record flow, the volumetric flow rate per unit time at a temperature range (℃) (1), ATM (atmospheric pressure)
Panasonic Air Flow Monitor EWA2 completed with Newly installed MODBUS(RTU) communication function
Panasonic Air Flow Monitor EWA2 has been supported by data obtained on the site can be transmitted to the recorder data light (DLL). Detailed data management can be achieved easily. There are also some features of this Panasonic Air Flow Monitor EWA2 product, those are:1. Zero energy losses
Any obstacles in the measurement of the pipe system for ultrasonic detection, causing a loss of pressure zero.
2. Zero energy losses
R.S. (Meter reading) Accuracy applies the accuracy of all readings in the range of flow rates. Therefore, the flow rate in the range until the low flow rate can be read with high accuracy.
3. It can be used in the loop pipes
It can measure the live broadcast and vice versa. Can be measured is transferred between buildings air consumption.
4. It can be used in plumbing circles
Pulse output and analog output current is available. It can be used for the connection.
Panasonic Air Flow Monitor EWA2 in combination with Eco-POWER METER and KW Watcher to visualize all aspects of energy use
Panasonic Air Flow Monitor EWA2 can also be used in combination with Eco-POWER METER and KW Watcher to visualize all aspects of energy use in one place, such as:1. Connect the output pulse of air flow control Aako- POWER meters.
2. Display the graph of electricity, heat, compressed air and the use of nitrogen gas. It includes the other data that have been collected by the light of the data recorder (DLL) using computer programs KW observer. This helps to use air / nitrogen compressed gas from several viewpoints electrical analysis.