PLC Type KV Keyence , Name Input / Output PLC :

INPUT PLC :
0000 ; Push Button Start
0001 ; Push Button Stop
0002 ; Micro Switches Wire Out
0003 ; Motor Feedback Alarm

OUTPUT PLC :
0500 ; Speed Control Motor ( Motor Running )
0501 ; Single Solenoid Wire Cutters 


PLC Keyence Programming :

Download Picture : PLC Keyence Programming

Please Download Programming for KV Builder : PLC Keyence Programming


Reading PLC Programming for Binding Machine :
Step 1 :
If 0002 = OFF And 0003 = OFF Then ALL Outputs =OFF ( Master Control = OFF ).
Step 2 :
If 0000 = ON And 0001 = OFF Then 1000 = Hold ON ( Latching ) And 1001 = Momentary ON ( Diff. UP).
Step 3 :
a. If 1001 = ON And T000 = OFF Then 1002= Hold ON ( Latching ) And T000 Activated.
b. If 1000 = ON And T002 = ON And T000 = OFF Then 1002 = Hold ON ( Latching ) And T000 Activated.
Step 4 :
If T000 = ON And T001 = OFF Then 1003 = Hold ON ( Latching ) And T001 Activated.
Step 5 :
If T001 = ON And T002 = OFF Then 1004 = Hold ON ( Latching ) And T002 Activated.
Step 6 :
a. If 1002 = ON Then 0500 = ON.
b. If 1003 = ON Then 0501 = ON.


For Setting Spiral Length :
Setting Spiral Length Timer Keyence T000

See : Simulation Make Timer PLC

See : PLC for Forming of Spiral for Binding Machine