SCADAPack 50 is the Schneider battery-powered wireless data logger for remote process monitoring. The superb quality of internal battery power provides maintenance-free up to 5 years of autonomy. This is a super compact autonomous device that monitors analog/discrete or Modbus inputs. SCADAPack 50 data logger with IP68 rate is for use in applications within environments where the protection required.
Schneider battery-powered wireless data logger commonly used in a wide variety of applications including gas distribution systems, water infrastructure monitoring, as well as bulk storage level monitoring and more. The example in a typical installation, the data log will be stored periodically in the unit and then transmitted to the host once per-day.
Looked from the host perspective, SCADAPack 50 Schneider battery-powered wireless data logger also provides SP50 network that compatible to the Schneider’s StruxureWare SCADA Expert ClearSCADA. By seizing the embedded drivers and easy-use interface, users can provide higher level of networking systems. Using the ClearSCADA users also have chance to use it as a gateway into any of third-party host.
The SCADAPack 50 Schneider battery-powered wireless data logger also offers quick installation and simple configuration. The quick installation enables super cost-effective of deployment solutions while the simple configuration enable you to remote assets through local interface or network from host.
The common markets and applications of SCADAPack 50 Schneider battery-powered wireless data logger are as follows:
- Cathodic protection of pipelines
- Pressure and flow monitoring in gas distribution includes leak detection
- Power monitoring
- In bulk storage facilities and isolated reservoir it used as monitoring levels
- Sewer overflows and discharge monitoring in wastewater process
- SCADAPack 50 data loggers is applicable on operating temperature from -25 to +60 degree Celsius (-13 to 140 Farenheit)
- Powerful and long-last 3.6 V Lithium Thionyl Chloride battery
- RS-485 port with maximum transfer rate up to 38400 bit/s
- Support various types of modems frequencies
- 3G Five Bands (800/850/900/1900/2100 MHz) UMTS/HSDPA + WCDMA/FDD or Quad Band GSM (850/900/1800/1900 MHz)
- 2G Quad-Band GSM (850/900/1800/1900 MHz)
Schneider battery-powered wireless data logger commonly used in a wide variety of applications including gas distribution systems, water infrastructure monitoring, as well as bulk storage level monitoring and more. The example in a typical installation, the data log will be stored periodically in the unit and then transmitted to the host once per-day.
Schneider battery-powered wireless data logger distributed through a GSM network as binary data files
Using Schneider battery-powered wireless data logger, However users still have lots of chance to choose among available sampling method and transmission rates. The files are distributed through a GSM network as binary data files in the form of SMS PDU format. On the other end, users can take benefit of any GSM modem (Hayes commands capable) to receive the files. They can choose 2G or 3G network connectivity type. A WAN connection in addition, can be obtained for larger systems with many of data loggers. Through a WAN connection, users can conduct direct connection to the local operator’s SMS server.Looked from the host perspective, SCADAPack 50 Schneider battery-powered wireless data logger also provides SP50 network that compatible to the Schneider’s StruxureWare SCADA Expert ClearSCADA. By seizing the embedded drivers and easy-use interface, users can provide higher level of networking systems. Using the ClearSCADA users also have chance to use it as a gateway into any of third-party host.
The Benefits of Schneider battery-powered wireless data logger SCADAPack 50
For remote assets monitoring systems, SP50 Schneider battery-powered wireless data logger network delivers a cost-effective and versatile system design. The availability of a wide variety of inputs, the unit even possible for the combination of analog, digital and modbus inputs all at once. Another subtle benefit of the battery-powered data logger is the maintenance-free networks for up to 5 years autonomy remote assets.The SCADAPack 50 Schneider battery-powered wireless data logger also offers quick installation and simple configuration. The quick installation enables super cost-effective of deployment solutions while the simple configuration enable you to remote assets through local interface or network from host.
The common markets and applications of SCADAPack 50 Schneider battery-powered wireless data logger are as follows:
- Cathodic protection of pipelines
- Pressure and flow monitoring in gas distribution includes leak detection
- Power monitoring
- In bulk storage facilities and isolated reservoir it used as monitoring levels
- Sewer overflows and discharge monitoring in wastewater process
- SCADAPack 50 data loggers is applicable on operating temperature from -25 to +60 degree Celsius (-13 to 140 Farenheit)
- Powerful and long-last 3.6 V Lithium Thionyl Chloride battery
- RS-485 port with maximum transfer rate up to 38400 bit/s
- Support various types of modems frequencies
- 3G Five Bands (800/850/900/1900/2100 MHz) UMTS/HSDPA + WCDMA/FDD or Quad Band GSM (850/900/1800/1900 MHz)
- 2G Quad-Band GSM (850/900/1800/1900 MHz)