GE Fanuc Series 90 Family





The GE Fanuc Series 90 are easy to install and organize, present sophisticated programming attributes, and are well-matched with the PLCs Series 90-70. The 341 and lower PLCs Series 90-30 and PLC Series 90-20 utilize an 80188 microprocessor. The series of 35x and 36x 90-30 PLCs utilize an 80386EX microprocessor. The 90-30 PLCs of 37x series utilize a 586 microprocessor. The Micro PLC Series 90 uses the microprocessor of H8. Both basic housekeeping and program execution tasks for instance diagnostic routines, scanners of input/output, and processing alarm are supported. The firmware system also includes routines to correspond with the programmer. These routines give for the download and upload of application programs, status information return, and the PLC control.

The program of application (user logic) that controls the last part process to which the PLC is applied is controlled by a committed ISCP (Instruction Sequencer Coprocessor) in the PLC Series 90-30. The ISCP is executed in hardware in the Model 313 and higher and in software in the systems of Model 311, and the PLC Micro. The hardware-based ISCP and microprocessor the can implement concurrently, permitting the microprocessor to check communications while the ISCP is executing the application program bulk; though, the microprocessor has to perform the function blocks of non-Boolean.

Faults happen in the PLC Series 90-20, Series PLC 90-30, and the Micro PLC when convinced failures or conditions occur that influence the performance and operation of the system. These situations may influence the capability of the PLC to control a process or machine. Other situations may only perform as an attentive, for instance a low signal of battery to specify that the voltage of the battery keeping the memory is low and should be changed. The failure or condition is called a fault. The faults are handled by an alarm processor software function that records the errors in either the I/O fault table or the PLC fault table. (CPUs Model 331 and higher also time stamp the errors.) These tables can be showed throughout the software of programming on the I/O Fault Table and PLC Fault Table screens in the software of Logicmaster 90-30/20/Micro with the status and control functions.

The PLC Series 90-20 offers a platform of cost-effective for low count applications of I/O. The main objectives of the PLC Series 90-20 are as follows:
• To offer a small PLC that is simple to utilize, install, maintain, and upgrade.
• To present a family-compatible PLC with cost-effective.
• To give easier system incorporation via standard protocols and communication hardware.

The Micro PLC Series 90 also offers a cost-effective platform for lower count applications of I/O. The main goals of the Micro PLC are the similar as those for the Series 90-20. Additionally, the Micro presents the following:
• The Micro PLC has the power supply, CPU, inputs and outputs they are built into one compact machine.
• The majority models also have a high-speed counter.
• It is very easy to configure. Because the power supply, CPU, and I/Os are all built into one device.