Mosaic of REER is a modular PLC programming that has a complete, easily configured to protect the machine in which all the components that can be separated from each other by placing the system remains in a large module. Device support controller consisting of a processor, I / O, even its power supply is integrated with several security sensors and commands, such as light curtains safety, laser scanners, mechanical switches, mats, emergency stop, control two hands, concentrating management of these in, single flexible device so as to form a control system that can be decentralized in a closet far in connection with the master unit.
For consideration when setting the system, has a mosaic of modular specifications Power supply (Vdc): 24 ± 20% Operating temperature (° C): -10 ... 55 ° C Dimensions (HxWxD): 99 x 22.5 x 114.
Advantages of Using Modular Mosaic from REER
Modular controller is widely used in applications within the plant control system because it offers many advantages compared to traditional security solutions based on the following components:- Able to support the construction of the electrical cabinet that is fast, simple, does not require a large space and safe
- Only requires fewer components so that wiring is also simpler
- Use simple and based on logical configuration single programming so becomes easier to do
- The process set up tamper-proof safety systems easier to machine maintenance through the MCM memory card and can be done quickly and efficiently.
Directives and standards Modular Mosaic from REER
Modular PLC is supported by MSD (Mosaic Safety Designer) software capable of performing the process to create complex logical conditions using logical operators and safety functions, such as muting, timers, counters, memories, etc. through a simple, intuitive graphical interface configuration. User can install the software on the PC by following the directives and modular standards as below:- 2006/42 / EC "Machinery Directive"
- 2004/108 / EC "Electromagnetic Compatibility (EMC)"
- 2006/95 / EC "Low Voltage Directive (LVD)"
- CEI EN 61131-2: "Programmable Controllers, Part 2: Equipment requirements and tests"
- EN ISO 13849-1: "Safety of machinery: Safety-related parts of control systems –
- Part 1: General principles for design "
- EN ISO 13849-2: "Safety of machinery: Safety-related parts of control systems - Part 2: Validation"
Configurable modular safety controller using a logical configuration of a single programming software
Mosaic of REER was designed using a modular SIL3 / PLE Mosaic Safety Controller to manage the process of laser scanners, safety light curtains, mechanical switches, photo cells, two-hand control, and an emergency stop has been concentrated management in one flexible, single device. Security sensors and commands are monitored by Mosaic decentralized in remote cabinets and connected to the master unit M1, MCT1 and MCT2 MCM module via memory card.Mosaic Modular Controller configuration via the MSD (Mosaic Safety Designer
Mosaic Modular controller has a simple standard configuration that consists of a master unit M1 is configured via the MSD (Mosaic Safety Designer) is provided with each unit master at no additional cost and a maximum of 14 expansion units are connected to the M1 via the MSC proprietary bus. To support the performance of the system configuration specification Max allowed is: 128 inputs, 16 pairs of OSSD, 16 responses Restart e / o interlock input and 32 output status with safety levels: SIL 3 - SILCL 3 - PL e - Cat. 4 - Type 4.For consideration when setting the system, has a mosaic of modular specifications Power supply (Vdc): 24 ± 20% Operating temperature (° C): -10 ... 55 ° C Dimensions (HxWxD): 99 x 22.5 x 114.